Mitsubishi Electric FR-F820-04750 Instruction Manual page 442

Hide thumbs Also See for FR-F820-04750:
Table of Contents

Advertisement

(T) Multi-Function Input Terminal Parameters
Input terminal function assignment
● Using Pr. 178 to Pr. 189, set the functions of the input terminals
● Refer to the following table and set the parameters.
Setting
0
1
2
3
4
5
6
7
8
10
11
12
13
14
16
18
24
25
28
37
38
39
40
46
47
48
50
51
60
61
62
64
Tab. 5-126: Input terminal function assignment (1)
5 - 280
Signal
Function
name
Pr. 59 = 0 (initial
value)
RL
Pr. 59 ≠ 0
Pr. 59 = 0 (initial
value)
RM
Pr. 59 ≠ 0
Pr. 59 = 0 (initial
value)
RH
Pr. 59 ≠ 0
RT
Second function selection
AU
Terminal 4 input selection
JOG
Jog operation selection
Selection of automatic restart after instantaneous
power failure, flying start
CS
Electronic bypass function
OH
External thermal relay input
15-speed selection
REX
(Combination with multi-speeds of RL, RM, and RH)
Inverter run enable signal (FR-HC2/FR-CV/FR-CC2
X10
connection)
FR-HC2/FR-CC2 connection, instantaneous power
X11
failure detection
X12
PU operation external interlock
X13
External DC injection brake operation start
X14
PID control valid terminal
PU/External operation switchover
X16
(External operation with X16-ON)
X18
V/F switchover (V/F control with X18-ON)
Output stop
MRS
Electronic bypass function
STP
Start self-holding selection
(STOP)
X28
Start-time tuning start external input
X37
Traverse function selection
PDI1
PID multistage set point setting 1
PDI2
PID multistage set point setting 2
PDI3
PID multistage set point setting 3
TRG
Trace trigger input
TRC
Trace sampling start/end
X48
Power failure stop external
SQ
Sequence start
X51
Fault clear
Forward rotation command
STF
(Assignable to the STF terminal (Pr. 178) only)
Reverse rotation command
STR
(Assignable to the STR terminal (Pr. 179) only)
RES
Inverter reset
X64
During retry
Low-speed operation
command
Remote setting (setting clear)
Middle-speed operation
command
Remote setting (deceleration)
High-speed operation
command
Remote setting (acceleration)
Related parameter
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 232 to Pr. 239
Pr. 59
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 232 to Pr. 239
Pr. 59
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 232 to Pr. 239
Pr. 59
Pr. 44 to Pr. 51, Pr. 450 to Pr. 463,
Pr. 569, Pr. 832, etc.
Pr. 267
Pr. 15, Pr. 16
Pr. 57, Pr. 58, Pr. 162 to Pr. 165,
Pr. 299, Pr. 611
Pr. 57, Pr. 58, Pr. 135 to Pr. 139,
Pr. 159
Pr. 9
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 232 to Pr. 239
Pr. 30, Pr. 599
Pr. 30
Pr. 79
Pr. 10 to Pr. 12
Pr. 127 to Pr. 134, Pr. 575 to
Pr. 577
Pr. 79, Pr. 340
Pr. 80, Pr. 81, Pr. 800
Pr. 17
Pr. 57, Pr. 58, Pr. 135 to Pr. 139,
Pr. 159
Pr. 250
Pr. 95
Pr. 592 to Pr. 597
Pr. 1460 to Pr. 1466
Pr. 1020 to Pr. 1047
Pr. 1020 to Pr. 1047
Pr. 261 to Pr. 266, Pr. 294, Pr. 668
Pr. 414
Pr. 414
Pr. 250
Pr. 250
Pr. 75
Pr. 127 to Pr. 134
Parameters
Refer to
page
5-57
5-108
5-57
5-108
5-57
5-108
5-285
5-249
5-139
5-409,
5-417
5-327
5-145
5-57
5-532
5-532
5-116
5-525
5-347
5-116
5-38
5-283
5-327
5-287
5-321
5-340
5-347
5-437
5-437
5-426
5-433
5-433
5-287
5-287
5-60
5-347