Parameter List
Pr.
Pr.
Name
group
1132
A626
Pre-charge change increment amount
Second pre-charge change increment
1133
A666
amount
1136
A670
Second PID display bias coefficient
1137
A671
Second PID display bias analog value
1138
A672
Second PID display gain coefficient
1139
A673
Second PID display gain analog value
Second PID set point/deviation input
1140
A664
selection
Second PID measured value input
1141
A665
selection
1142
A640
Second PID unit selection
1143
A641
Second PID upper limit
1144
A642
Second PID lower limit
1145
A643
Second PID deviation limit
1146
A644
Second PID signal operation selection
Second output interruption detection
1147
A661
time
Second output interruption detection
1148
A662
level
1149
A663
Second output interruption cancel level
1150
A810
to
to
PLC function user parameters 1 to 50
1199
A859
1211
A690
PID gain tuning timeout time
1212
A691
Step manipulated amount
1213
A692
Step response sampling cycle
1214
A693
Timeout time after the maximum slope
1215
A694
Limit cycle output upper limit
1216
A695
Limit cycle output lower limit
1217
A696
Limit cycle hysteresis
1218
A697
PID gain tuning setting
1219
A698
PID gain tuning start/status
1300
N500
to
to
Communication option parameters.
1343,
N543,
1350
N550
For details, refer to the Instruction Manual of the option.
to
to
1359
N559
1361
A440
Detection time for PID output hold
1362
A441
PID output hold range
1363
A447
PID Priming time
1364
A448
Stirring time during sleep
1365
A449
Stirring interval time
1366
A627
Sleep boost level
Tab. 5-2:
Parameter overview (by number) (19)
5 - 20
Minimum
Setting range
setting
increments
0 to 100%, 9999
0.01%
0 to 100%, 9999
0.01%
0 to 500, 9999
0 to 300%
0 to 500, 9999
0 to 300%
1 to 5
1 to 5, 101 to 105
0 to 43, 9999
0 to 100%, 9999
0 to 100%, 9999
0 to 100%, 9999
0 to 3, 10 to 13
0 to 3600 s, 9999
0 to 590 Hz
0.01 Hz
900 to 1100%
0 to 65535
1 to 9999 s
900 to 1100%
0.01 to 600 s
0.01 s
1 to 9999 s
900 to 1100%
900 to 1100%
0.1 to 10%
0, 100 to 102, 111, 112,
121, 122, 200 to 202, 211,
212, 221, 222
(0), 1, 8, (9, 90 to 96)
0 to 900 s
0 to 50%, 9999
0 to 360 s, 9999
0 to 3600 s
0 to 1000 h
0 to 100%, 9999
0.01%
Initial value
Refer
to page
FM
CA
9999
5-379
9999
5-379
0.01
9999
5-375
0.1%
20%
5-375
0.01
9999
5-375
0.1%
100%
5-375
1
2
5-347
1
3
5-347
1
9999
5-347
0.1%
9999
5-347
0.1%
9999
5-347
0.1%
9999
5-347
1
0
5-347
0.1 s
1
5-347
0 Hz
5-347
0.1%
1000%
5-347
1
0
5-433
1 s
100 s
5-367
0.1%
1000%
5-367
1 s
5-367
1 s
10 s
5-367
0.1%
1100%
5-367
0.1%
1000%
5-367
0.1%
1%
5-367
1
0
5-367
1
0
5-367
0.1 s
5 s
5-398
0.1%
9999
5-398
0.1 s
9999
5-398
0.1 s
15 s
5-398
0.1 h
0 h
5-398
9999
5-398