Parameters
Pr.
Pr.
Name
group
Second motor induced voltage
738
C230
constant (phi f )
739
C231
Second motor Ld decay ratio
740
C232
Second motor Lq decay ratio
Second starting resistance tuning
741
C282
compensation
Second motor magnetic pole detection
742
C285
pulse width
743
C206
Second motor maximum frequency
744
C207
Second motor inertia (integer)
745
C208
Second motor inertia (exponent)
746
C233
Second motor protection current level
753
A650
Second PID action selection
Second PID control automatic
754
A652
switchover frequency
755
A651
Second PID action set point
756
A653
Second PID proportional band
757
A654
Second PID integral time
758
A655
Second PID differential time
759
A600
PID unit selection
760
A616
Pre-charge fault selection
761
A617
Pre-charge ending level
762
A618
Pre-charge ending time
763
A619
Pre-charge upper detection level
764
A620
Pre-charge time limit
765
A656
Second pre-charge fault selection
766
A657
Second pre-charge ending level
767
A658
Second pre-charge ending time
Second pre-charge upper detection
768
A659
level
769
A660
Second pre-charge time limit
774
M101
Operation panel monitor selection 1
775
M102
Operation panel monitor selection 2
776
M103
Operation panel monitor selection 3
A681
777
4 mA input check operation frequency
T053
A682
778
4 mA input check filter
T054
Operation frequency during
779
N014
communication error
791
F070
Acceleration time in low-speed range
792
F071
Deceleration time in low-speed range
Pulse increment setting for output
799
M520
power
800
G200
Control method selection
Tab. 5-2:
Parameter overview (by number) (14)
FR-F800
Minimum
Setting range
setting
increments
0 to 5000 mV/(rad/s),
0.1 mV/(rad/s)
9999
0 to 100%, 9999
0 to 100%, 9999
0 to 200%, 9999
0 to 6000 μs,
10000 to 16000 μs,
9999
0 to 400 Hz, 9999
0.01 Hz
10 to 999, 9999
0 to 7, 9999
100 to 500%, 9999
0, 10, 11, 20, 21, 50, 51,
60, 61, 70, 71, 80, 81, 90,
91, 100, 101, 1000, 1001,
1010, 1011, 2000, 2001,
2010, 2011
0 to 590 Hz, 9999
0.01 Hz
0 to 100%, 9999
0.01%
0.1 to 1000%, 9999
0.1 to 3600 s, 9999
0.01 to 10 s, 9999
0.01 s
0 to 43, 9999
0, 1
0 to 100%, 9999
0 to 3600 s, 9999
0 to 100%, 9999
0 to 3600 s, 9999
0, 1
0 to 100%, 9999
0 to 3600 s, 9999
0 to 100%, 9999
0 to 3600 s, 9999
1 to 3, 5 to 14, 17, 18, 20,
23 to 25, 34, 38, 40 to 45,
50 to 57, 61, 62, 64, 67 to
69, 81 to 96, 98, 100,
9999
0 to 590 Hz, 9999
0.01 Hz
0 to 10 s
0.01 s
0 to 590 Hz, 9999
0.01 Hz
0 to 3600 s, 9999
0 to 3600 s, 9999
0.1, 1, 10, 100, 1000 kWh
0.1 kWh
9, 20
Parameter List
Initial value
Refer
to page
FM
CA
9999
5-310
0.1%
9999
5-310
0.1%
9999
5-310
0.1%
9999
5-310
1 μs
9999
5-310
9999
5-310
1
9999
5-310
1
9999
5-310
0.1%
9999
5-310
1
0
5-347
9999
5-347
9999
5-347
0.1%
100%
5-347
0.1 s
1 s
5-347
9999
5-347
1
9999
5-375
1
0
5-379
0.1%
9999
5-379
0.1 s
9999
5-379
0.1%
9999
5-379
0.1 s
9999
5-379
1
0
5-379
0.1%
9999
5-379
0.1 s
9999
5-379
0.1%
9999
5-379
0.1 s
9999
5-379
1
9999
5-193
1
9999
5-193
1
9999
5-193
9999
5-274
0 s
5-274
9999
5-452
0.1 s
9999
5-99
0.1 s
9999
5-99
1 kWh
5-247
1
20
5-38
5 - 15