Operation in Timer/Twin Timer Selection Mode

Select whether the H5CX is used as a timer or a twin timer in timer/twin timer selection mode. The H5CX is also equipped with a DIP switch monitor
function, a convenient function that enables the settings of the DIP switch pins to be confirmed using the front display.
Power ON
+
1
1 s min.
Note 1. When the mode is changed to timer/twin timer selection mode, the present value is reset and output turns OFF. Timing operation is not
performed in timer/twin timer selection mode.
2. Setting changes made in timer/twin timer selection mode are enabled when the mode is changed to run mode. If settings are changed, the
HC5X is automatically reset (present value initialized, output turned OFF).
To change the mode to timer/twin timer selection mode, hold
down the
The
key must be pressed before the
MODE
If the
1
Timer/Twin
Select either timer operation or twin timer operation
timer selection
using the
(Timer)
Note: The H5CX is factory-set for timer operation.
DIP switch
monitor
Confirm the status of DIP switch pins 1 to 8 using
the
Note 1. This display is not supported with H5CX-L8@.
2. This display is only possible when DIP switch pin 1
(DIP switch settings enable/disable) is set to ON (enable).
Example
ON
OFF
1
key for 1 s min. with the
MODE
key held down.
key.
1
key is pressed first, the mode will not change.
keys.
(Twin timer)
keys.
1
2
3
4
5
6
7
8
Multifunction Digital Timer
1
Indicates that DIP switch pin 8 is ON.
Indicates that DIP switch pin 7 is OFF.
Indicates that DIP switch pin 6 is ON.
Indicates that DIP switch pin 5 is OFF.
Indicates that DIP switch pin 4 is ON.
Indicates that DIP switch pin 3 is OFF.
Indicates that DIP switch pin 2 is ON.
Indicates that DIP switch pin 1 is ON.