U0310/Uf0310 Self-Contained Water-Cooled - Welbilt Manitowoc NEO UDE0065A Technician's Handbook

Undercounter ice machines
Hide thumbs Also See for Manitowoc NEO UDE0065A:
Table of Contents

Advertisement

U0310/UF0310 SELF-CONTAINED WATER-COOLED

NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Around Ice
Machine
°F/°C
70/21
80/27
90/32
100/38
110/43
Times in minutes
24 Hour Ice Production
Air Temp.
Around Ice
Machine °F/°C
70/21
80/27
90/32
100/38
110/43
Based on average ice slab weight of 2.44 - 2.75 lb (1107 – 1247 g).
Regular cube derate is 7%
Water regulating valve set to maintain 235 PSIG discharge pressure
Condenser water usage = 149 gallons per 100 lbs of ice a 90°F/70°F
Operating Pressures
Air Temp.
Around Ice
Machine
°F/°C
50/10
70/21
80/27
90/32
100/38
110/43
Suction pressure drops gradually throughout the freeze cycle
Part Number 000014797 Rev02 05/19
Freeze Time
Water Temperature °F/°C
50/10
11.5-13.2
11.3-12.9
10.0-11.5
11.5-13.2
10.2-11.7
12.6-14.3
10.4-11.9
12.6-14.3
10.6-12.2
12.8-14.7
50/10
270
305
300
295
290
Freeze Cycle
Discharge
Pressure
PSIG
230-240
230-240
235-240
235-240
235-250
235-255
70/21
12.0-13.7
12.3-14.0
13.1-15.0
13.5-15.4
13.8-15.7
Water Temperature °F/°C
70/21
275
270
250
250
245
Suction
Discharge
Pressure
Pressure
PSIG
50-24
150-175
50-25
150-175
50-26
155-175
55-27
165-180
60-27
165-180
60-28
165-180
Harvest
Time
90/32
1.0-2.5
90/32
260
255
240
235
230
Harvest Cycle
Suction
Pressure
PSIG
75-90
75-90
75-95
80-100
80-100
80-100
PSIG
227