REMEDIAL CLEANING

This procedure can be performed between the bi-annual
detailed descaling and sanitizing cycles. This procedure
does not require removing the ice from the bin.
Press the On/Off button after ice falls from the
Step 1
evaporator at the end of a Harvest cycle. Or, press the On/
Off button and allow the ice to melt off the evaporator.
Never use anything to force ice from the evaporator.
Damage may result.
Wear rubber gloves and safety goggles (and/or face
shield) when handling Ice Machine Cleaner/Descaler
or Sanitizer.
To start a cycle, press the Clean button. Water
Step 2
will flow through the water dump valve and down the
drain. Wait until the water trough refills, then add the
proper amount of ice machine cleaner/descaler to the
water trough.
Model
U0140/UF0140
U0190/UF0190
U0240/UF0240
U0310/UF0310
Wait until the cycle is complete (approximately 22
minutes) then press the On/Off button.
Part Number 000014797 Rev02 05/19
Caution
,
Warning
n
Amount of Cleaner/Descaler
Part Number 9405463
2 ounce (60 ml)
5 ounces (150 ml)
5 ounces (150 ml)
5 ounces (150 ml)