Safety Limit Feature - Welbilt Manitowoc NEO UDE0065A Technician's Handbook

Undercounter ice machines
Hide thumbs Also See for Manitowoc NEO UDE0065A:
Table of Contents

Advertisement

SAFETY LIMIT FEATURE

In addition to the standard safety controls, your
Manitowoc ice machine features built-in safety limits that
will stop the ice machine if conditions arise which could
cause a major component failure.
Service Light: The Service light energizes whenever a
safety limit has been exceeded.
Safety Limit 1
If the freeze time reaches 45 minutes, the control board
automatically initiates a harvest cycle.
After 3 consecutive 45minute cycles, control board
light SL#1 along with the touch pad service (wrench)
light will flash on/off at 1 second intervals.
If 6 consecutive 45-minute freeze cycles occur, the ice
machine stops and the SL#1 light on the control board
and the Service (wrench) light on the touch pad will be
on continuously.
Safety Limit 2
If the harvest time reaches 3.5 minutes, the control
board automatically energizes the water pump and
extends the harvest cycle another 3.5 minutes (7
minutes total).
If the ice damper does not open and close within the
7 minute harvest cycle the ice machine enters a water
thaw cycle for 170 seconds.
If the damper does not open/close within the 170
second thaw cycle, a second thaw cycle starts.
The control board automatically initiates a freeze
sequence when the thaw cycle(s) is complete.
If 3 consecutive 7 minute harvest/thaw cycles occur,
the ice machine stops and the SL#2 light on the control
board and the Service (wrench) light on the touch pad
will be on continuously.