Model Numbers
This manual covers the following models:
Self-Contained
Air-Cooled
UDF0140A
UYF0140A
URF0140A
UDP0140A
UYP0140A
UDF0190A
UYF0190A
UDF0240A
UYF0240A
UDF0310A
UYF0310A
URF0310A
UDP0310A
UYP0310A
HOW TO READ A MODEL NUMBER
Nominal production
@70/50
0140-Produces~140#/day
Ice machine
0190-Produces~190#/day
series
0240-Produces~240#/day
U-Undercounter
0310-Produces~310#/day
U
D
F
0 1 4 0
Ice type
Refrigerant type
R-Regular
P-R290(propane)
D-Dice
F-R404A(four)
Y-Half-dice
T-R410A(ten)
F-Flake
B-R600A(butane)
N-Nugget
E-R134a(eight)
G-Gourmet
Part Number: 040005890 Rev 01 06/18
General Information
Self-Contained
Water-Cooled
UDF0240W
UYF0240W
UDF0310W
UYF0310W
URF0310W
Electrical configuration
161-115/60/1
261-208~230/60/1
251-220~240/50/1(S=230)
263-208~230/60/3
271-200/50-60/1
273-200/50-60/3
453-380~415/50/3
463-460/60/3
A - 261 ZQS
Condenser type
Power cord option
A-Air cooled
Blank-Junction Box
W-Water cooled
Z-Cord without plug
N-Remote
B-NEMA plug(USA)
(traditional)
F-Schuko plug(EU)
C-CVD(remote)
G-13A blade(GBR)
I-Oblique V blades(AUS)
Special Use
Blank-General use
Q-Coated condenser
H-High pressure
M-Marine
P-Correctional
T-Top air discharge
X-LuminIce
L-Lever
V-Space Maker
Market identifier
Blank-Not market Specific
S-Saudi Arabia(GCC)
K-Korea(KC)
C-China(ccc)
Section 1
SHIPPING WEIGHT
Model Family
UF0140
UF0190
UF0240
UF0310
Accessories
Contact your Manitowoc distributor for these optional
accessories:
BIN CASTER
Replaces standard legs.
ARCTIC PURE WATER FILTER SYSTEM
Engineered specifically for Manitowoc ice machines,
Arctic Pure water filters are an efficient, dependable, and
affordable method of inhibiting scale formation, filtering
sediment, and removing chlorine taste and odor.
MANITOWOC CLEANER AND SANITIZER
Manitowoc Ice Machine Cleaner and Sanitizer are available
in convenient 16 oz. (473 ml) and 1 gal (3.78 l) bottles. These
are the only cleaner and sanitizer approved for use with
Manitowoc products.
LUMINICE®
The LuminIce® growth inhibitor recirculates the air in the ice
machine foodzone over a UV bulb. This process will inhibit
the growth of common micro-organisms on all exposed
foodzone surfaces.
NOTE: LuminIce® bulbs require replacement on a yearly
basis.
CLEANUP PROCEDURE FOR ACCIDENTAL BULB
BREAKAGE
The cleanup procedure is identical to the procedure used
to clean up compact fluorescent (CFL) or fluorescent tube
lights. These lights contain a small amount of mercury sealed
within a glass tube. Breaking these types of lights will release
mercury and mercury vapor. The broken bulb can continue to
release mercury vapor until it is cleaned up and removed.
The latest EPA procedures can be viewed on their website at
www.epa.gov/cfl/cflcleanup.html.
Shipping Weight
153 lbs (69 kg)
153 lbs (69 kg)
160 lbs (73 kg)
211 lbs (96 kg)
9