Control Board Test Mode; Operating Ice Machine With Bin And Touch Pad; Removed - Welbilt Manitowoc NEO UDE0065A Technician's Handbook

Undercounter ice machines
Hide thumbs Also See for Manitowoc NEO UDE0065A:
Table of Contents

Advertisement

CONTROL BOARD TEST MODE

NOTE: The ice damper/bin switch can be open or closed
and does not effect the operation of the test mode.
To enter the test mode press and hold the test switch
on the control board for 3 seconds. Refer to "Electronic
Control Board UF Models" on page 243 for test button
location. The control board test mode performs the
following functions for a 2 minute time period:
Energizes all control board relays
Energizes all control board lights
Energizes all touch pad control lights
After the 2 minute test period the control board will
complete 500 ice making cycles, then stop.
Canceling a test cycle:
To cancel a test cycle press the test button a second time.
Restarting a test cycle:
The test cycle will restart each time the test button is
pressed for a 3 second time period.

OPERATING ICE MACHINE WITH BIN AND TOUCH PAD

REMOVED

The ice machine is designed to allow diagnostic procedures
to be performed with the bin removed or to run ice
making cycles if a touch pad is defective. The touch pad is
attached to the bin and is disconnected during the removal
process. Use the control board test mode to operate the
ice machine without connecting the touch pad. Refer to
"Electronic Control Board UF Models" on page 243 for
test button location
NOTE: Software versions before 2.70 operate for 1 cycle
in test mode. Software versions after 2.70 operate for 500
cycles in test mode.
92
Part Number 000014797 Rev02 05/19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents