Ice Thickness Adjustment - Welbilt Manitowoc NEO UDE0065A Technician's Handbook

Undercounter ice machines
Hide thumbs Also See for Manitowoc NEO UDE0065A:
Table of Contents

Advertisement

ICE THICKNESS ADJUSTMENT

It is normal to have a dimple in the ice cube (a concave
indentation in the cube). Cube size is determined by
measuring the slab weight (the combined weight of all
cubes from one harvest cycle). To determine proper slab
weight follow the instructions listed below.
1. Ensure the air filter, front, and back panels are
installed properly and close the bin door.
2. During the third harvest cycle open the bin door and
catch the entire slab of ice.
3. Weigh the ice slab. The combined weight of all cubes
from one harvest should weigh between 200 - 270g
(7 - 9-oz). If the slab weight is within this range, the
ice machine is working properly and no further action
is needed. If the slab weight is not within this range or
you desire a slightly thicker or thinner cube, continue
to step four.
4. Remove the air filter, the two screws holding the front
panel in place and remove the front cover.
5. Locate the ice thickness control dial on the control
board (see below). Turn the dial clockwise for a
thicker cube or counter clockwise for a thinner cube.
6. Assure all panels and the air filter are reinstalled
properly and the bin door is closed. Repeat steps one
through three.
Part Number 000014797 Rev02 05/19
81

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents