WATER SYSTEM CHECKLIST

A water-related problem often causes the same symptoms
as a refrigeration system component malfunction.
Water system problems must be identified and eliminated
prior to replacing refrigeration components.
Water area (evaporator) is dirty
Descale as needed
Water inlet pressure not between 20 and 80 psig (1–5 bar,
138–552 kPa)
Install a water regulator valve or increase the water
pressure
Incoming water temperature is not between 40°F (3°C)
and 90°F (32°C)
If too hot, check the hot water line check valves in
other store equipment
Water filtration is plugged (if used)
Install a new water filter
Vent tube is not installed on water outlet drain
See Installation Instructions
Hoses, fittings, etc., are leaking water
Repair/replace as needed
Water valve is stuck open, closed or is leaking
Descale/replace as needed
Water is spraying out of the sump trough area
Stop the water spray
Water is leaking through the sump trough overflow
Set the water level 1/4"-3/8" below standpipe
Uneven water flow across the evaporator
Descale the ice machine
Water is freezing behind the evaporator
Correct the water flow
Plastic extrusions and gaskets are not secured to the
evaporator
Remount/replace as need.