Tripoli Screen Door - FPI P36 Owners & Installation Manual

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

®
REGENCY
OPTIONS
When installing the optional Tripoli Screen Door Series, a non-combustible material 12" (305mm) above the unit and 6" (153mm)
on each side must be used (see Diagram 1).
The Tripoli Screen Door Series also requires steel stud framing above and on each side of the unit (refer to Diagram 1).
Diagram 1
Fireplace with 1-1/2" (38mm) Facing Material
The hearth material must be brought past the Tripoli frame all the way to the unit
face, so there will be no gap between the face and the actual fi replace.
OPTIONS
A
1
36-1/4"
(921mm)
2
36-1/4"
(921mm)
* 'D' is Minimum height to combustible materials including the Minimum 2" (51mm) Top clearance to the Horizontal Vent.
FPI P36-4 Zero Clearance Direct Vent Gas Fireplace

TRIPOLI SCREEN DOOR

Option #1:
INSTALLATION NOTE:
P36
B
C
36-1/4"
14-1/4"
(921mm)
(362mm)
36-1/4"
13-3/4"
(921mm)
(349mm)
Fireplace with 1" (25mm) Facing Material
FRAMING DIMENSIONS
D
A
46"*
36-1/4"
(1168mm)
(921mm)
(921mm)
46"
36-1/4"
(1168mm)
(921mm)
(921mm)
Option #2:
P36D
B
C
36-1/4"
18-5/8"
(473mm)
(1168mm)
36-1/4"
18-1/8"
(460mm)
(1168mm)
D
46"*
46"
59