FPI P36 Owners & Installation Manual page 29

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

INSTALLATION
The P36 is approved for a 40 ft. straight vertical, with rigid pipe vent systems for
Propane and Natural Gas, as per the diagram 1.
The shaded area in the diagram 1 shows all allowable combinations of straight
vertical and offset to vertical terminations with rigid pipe vent systems for Propane
and Natural Gas. Maximum two 45
Vent must be supported at offsets.
Firestops are required at each fl oor level and whenever passing through
a wall.
Maintain clearances to combustibles.
FPI P36-4 Zero Clearance Direct Vent Gas Fireplace
o
elbows allowed.
Diagram 1
29