FPI P36 Owners & Installation Manual page 26

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

One 90
o
elbow = Two 45
Option
V
H + H1
A)
0' Min.
2' Max.
B)
1' Min.
3' Max.
C)
2' Min.
4' Max.
D)
3' Min.
5' Max.
E)
4' Min.
6' Max.
F)
5' Min.
7' Max.
G)
6' Min.
8' Max.
Lengths do not include
elbow indicated
One 90
o
elbow = Two 45
Option
V
H
A)
0' Min.
1' Max.
B)
1' Min.
2' Max.
C)
2' Min.
2' Max.
D)
3' Min.
2' Max.
E)
4' Min.
3 Max.
F)
5' Min.
4' Max. 10' Min. 7' Max.
G)
6' Min.
5' Max. 11' Min. 8' Max.
H)
7' Min.
6' Max. 12' Min. 9' Max.
Lengths do not include elbow indicated
26
Horizontal Venting with Two (2) 90
o
elbows.
W i t h t h e s e o p t i o n s ,
maximum total pipe length
is 30 feet with minimum
of 6 feet total vertical
and maximum 8 feet total
horizontal.
Please note minimum 1
o
foot between 90
elbows
is required.
Horizontal Venting with Three (3) 90
o
elbows.
V + V1
H + H1
With these options,
1' Min.
2' Max.
max. total pipe
3' Min.
3' Max.
length is 30 feet
with min. of 12 feet
5' Min.
4' Max.
total vertical and
7' Min.
5' Max.
max. 9 feet total
horizontal.
9' Min.
6' Max.
Please note min. 1
foot between 90
elbows is required.
o
Elbows
H1
o
Elbows
o
FPI P36-4 Zero Clearance Direct Vent Gas Fireplace
INSTALLATION
V

Advertisement

Table of Contents
loading

This manual is also suitable for:

P36-ng4P36-lp4

Table of Contents