This appliance is designed to be installed into cabinet units capable of
withstanding temperatures
80-90°C).
The rear wall or splashback the hob is to be fitted in front of must be
made of flame resitant material
If there is no oven to be built in below the hob it is recommended
that, an isolation shelf should be fitted to protect the user from high
temperatures. If the hob is to be installed above a working drawer,
then a partition should be fitted to protect the contents and user from
the heat generated during use. This should be fitted at least 15mm
below the hob. This panel should have a ventilation space at the rear
of greater than 30mm as shown in Fig. 10.
Never place perishable foods in the cupboard below the appliance.
65°C above ambient or greater (typically
Ventilation slot > 30mm
Fig. 10
15mm