The machine does not
turn on
The machine is in DEMO
mode.
The drip tray is quickly
filled.
The coffee grounds
container full icon remains
displayed.
The brew group cannot
be removed.
The brew group cannot
be inserted.
The coffee has too little
crema or is watery.
The machine is disconnected.
The standby button has been
pressed for more than 8 seconds.
This is normal. The machine uses
water to rinse the internal circuit
and brew group. Some water
flows through the internal system
directly into the drip tray.
The coffee grounds container
was emptied while the machine
was switched off.
The coffee grounds container
was placed back too fast.
The brew group is not positioned
correctly.
The coffee grounds container is
not removed.
The machine is still in the
descaling process.
The brew group is not in the
correct position.
The grinder is set to a coarse
setting.
The brew group is dirty.
Check if the power supply cord is
inserted correctly
Switch the machine off and then on
again.
Empty the drip tray when the 'drip tray
full' full indicator pops up through the
drip tray cover.
Place a cup under the dispensing
spout to collect rinsing water.
Always empty the coffee grounds
container while the machine is ON. If
the coffee grounds container is
emptied while the machine is switched
off, the coffee cycle counter is not
reset. In that case, the 'empty coffee
grounds container' message will stay
on the display even though the
container is not full.
Do not place back the coffee grounds
container until the screen message
prompts you to put it back
Close the maintenance door. Switch
the machine off and back on again.
Wait for the machine ready screen to
appear and then remove the brew
group.
Remove the coffee grounds container
before removing the brew group.
You cannot remove the brew group
when the descaling process is active.
First complete the descaling process
and then remove the brew group.
The brew group was not put in rest
position before it was placed back.
Make sure that the lever is in contact
with the base of the brew group and
that the hook of the brew group is in
the correct position.
Reset the machine by switching it on
and off. Place the drip tray and the
coffee grounds container back. Leave
the brew group out. Close the
maintenance door and switch the
machine on and off. Then try to
reinsert the brew group.
Adjust the grinder to a finer setting.
Clean the brew group. For thorough
cleaning, follow the monthly cleaning
procedure with the degreasing tablet.