FCC ID: K6610443250/IC ID: 511B-10443250
R
M
R
ACK
OUNT
EPEATER
VXR-9000-H
O
M
PERATING
ANUAL
VERTEX STANDARD CO., LTD.
4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan
VERTEX STANDARD
US Headquarters
10900 Walker Street, Cypress, CA 90630, U.S.A.
YAESU EUROPE B.V.
P.O. Box 75525, 1118 ZN Schiphol, The Netherlands
YAESU UK LTD.
Unit 12, Sun Valley Business Park, Winnall Close
Winchester, Hampshire, SO23 0LB, U.K.
VERTEX STANDARD HK LTD.
Unit 5, 20/F., Seaview Centre, 139-141 Hoi Bun Road,
Kwun Tong, Kowloon, Hong Kong
VXR-9000 FM R
O
M
EPEATER
PERATING
ANUAL
Vertex Standard Co., Ltd.

Advertisement

Table of Contents
loading

Summary of Contents for Vertex Standard VXR-9000-H

  • Page 1 FCC ID: K6610443250/IC ID: 511B-10443250 OUNT EPEATER VXR-9000-H PERATING ANUAL VERTEX STANDARD CO., LTD. 4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan VERTEX STANDARD US Headquarters 10900 Walker Street, Cypress, CA 90630, U.S.A. YAESU EUROPE B.V. P.O. Box 75525, 1118 ZN Schiphol, The Netherlands YAESU UK LTD.
  • Page 2 FCC ID: K6610443250/IC ID: 511B-10443250 VXR-9000 FM R EPEATER PERATING ANUAL Vertex Standard Co., Ltd.
  • Page 3 Important Note: Internal service work, programming, and accessory installations should only be performed by your authorized Vertex Standard Dealer. Dangerous conditions and/or possibly illegal operation may result from im- proper setup, programming, or internal modifications. AFETY...
  • Page 4 The internal speaker is located here. tions are explained on the pages to follow. VOL Knob This control knob adjusts the output level of the front speaker and external speaker jack on the back panel. VXR-9000 FM R EPEATER PERATING ANUAL Vertex Standard Co., Ltd.
  • Page 5 TEX STANDARD dealer. signal. When you enable this function, the signal-to- noise ratio can be improved by reducing the transmit- ted audio dynamic range. VXR-9000 FM R EPEATER PERATING ANUAL Vertex Standard Co., Ltd.
  • Page 6 Press (or Press and hold in for one second) the PF key the various power save feature (determined from your assigned to “Remote” to toggle the operating mode be- VERTEX STANDARD dealer) while the repeater oper- tween the “Remote” mode and “Local” mode. ates from the Backup Power Source.
  • Page 7 “Mid” level. assigned to “Test Tone” to generate the Test Tone Signal, as programmed by your VERTEX STANDARD dealer. Press (or press and hold in one second) this key again to return to the “Original” power level (determined via Press (or Press and hold in for one second) this key again programming by your VERTEX STANDARD dealer).
  • Page 8: Rear Panel Connectors

    (input or output), and its logic antenna, or the “TX” jack on the duplexer. The out- (for output ports only). put impedance requirement is 50 Ohms. VXR-9000 FM R EPEATER PERATING ANUAL Vertex Standard Co., Ltd.
  • Page 9 Pin 1: GND by your VERTEX STANDARD dealer. Chassis ground for all logic levels and power supply Pin 6: DISC OUT return.
  • Page 10 ( 300 ~ 3,000 Hz ) This pin is an output for low speed receiving data sig- nals (typically 1200 bps), with the data being extracted after the de-emphasis and low pass filter stages. VXR-9000 FM R EPEATER PERATING ANUAL Vertex Standard Co., Ltd.
  • Page 11: Installation

    When separate receive and sible. transmit antennas are used, high-Q narrow-band types may serve to minimize interaction. NEVER TRANSMIT WITHOUT HAVING A TRANSMIT ANTENNA CONNECTED TO THE TX ANTENNA JACK OF THE REPEATER. VXR-9000 FM R EPEATER PERATING ANUAL Vertex Standard Co., Ltd.
  • Page 12: Backup Power Supply

    Battery Charge switch (located on the PA Unit) is set to “ON.” BACKUP MAIN B ACK UP INPUT DC 13.6V Supplied DC Power Code Backup Battery (12 V, 55 Ah) YPICALLY ETUP VXR-9000 FM R EPEATER PERATING ANUAL Vertex Standard Co., Ltd.
  • Page 13: Supplied Accessories

    15-A Blade Fuse (Q0000075) ........... 1 FVP-25 Encryption Unit Knob Cap (RA0506900) ........... 6 FVP-35 Rolling Code Encryption Unit Name Plate (RA0508500) ..........1 MD-11 Desktop Microphone Operating Manual ............1 MH-25 Hand Microphone VXR-9000 FM R EPEATER PERATING ANUAL Vertex Standard Co., Ltd.
  • Page 14: Specifications

    Pre-emphasis : 6dB/oct (From 300 Hz to 3 kHz) Spurious Emission: 70dB below carrier Audio Distortion: 3.0 % @1 kHz Microphone Impedance: 600 ohm Specifications subject to change without notice or obligation. VXR-9000 FM R EPEATER PERATING ANUAL Vertex Standard Co., Ltd.
  • Page 15 FCC ID: K6610443250/IC ID: 511B-10443250 Part 15.21: Changes or modifications to this device not expressly ap- proved by Vertex Standard could void the user’s authorization to operate this device. VXR-9000 FM R EPEATER PERATING ANUAL Vertex Standard Co., Ltd.
  • Page 16 FCC ID: K6610443250/IC ID: 511B-10443250 Copyright 2005 No portion of this manual may be reproduced without the permission of VERTEX STANDARD CO., LTD. All rights reserved. VERTEX STANDARD CO., LTD. Printed in Japan 0504s-BE Vertex Standard Co., Ltd.