Data Source Setup - Furuno NAVpilot 711 Installation Manual

Table of Contents

Advertisement

9. Press the MENU key to return to the [NMEA0183 PORT1] menu.
10.Rotate the knob to select [INCOMING NMEA0183 DATA] then push the knob.
This display shows the NMEA0183 sentences currently being received.
11.Press the MENU key twice to return to the [NMEA0183 PORT SETUP] menu.
If you have equipment connected to NMEA0183 PORT2, set up the equipment similar
to how you set up the equipment in NMEA0183 PORT1.
Note: [PORT2] is not shown when [BOAT TYPE] is set to [EVCS BOAT].
3.8

Data Source Setup

Before doing this procedure, turn on all CAN bus equipment connected to the CAN bus
network of the NAVpilot.
SENSOR SYNC
When NavNet3 or NavNet TZtouch devises are connected to the same network with the
NAVpilot, the sensors connected to NavNet3 or NavNet TZtouch devices are available for
the NAVpilot. Do as follows to share the sensors:
1. The cursor is selecting [SENSOR SYNC]; push the knob.
2. Select [ON] or [OFF] then push the knob.
When [SENSOR SYNC] is set to [ON], the sensors connected to NavNet3 or NavNet
TZtouch devices are available for the NAVpilot.
Data source selection
Do as follows to select the data source.
1. Turn on all sensors then push the knob.
INCOMING NMEA0183 DATA
AAM
DBT
HDG
RMB
APB
DPT
HDM
RMC
BOD
GGA
HDT
ROT
BWC
GLL
MTW
THS
BWR
GNS
MWV
TLL
SENSOR SELECTION
SENSOR SYNC: ON
HEADING SENSOR
SPEED (STW)
SPEED (SOG)
POSITION SENSOR
WIND SENSOR
DEPTH SENSOR
TEMP SENSOR
3. INITIAL SETTINGS
VHW
ZDA
VTG
VWR
VWT
XTE
3-23