Shutdown and Cleaning

NOTICE
Failure to properly clean sprayer after each use will result
in hardened materials, damage to the sprayer, and the
warranty will no longer be valid.

Flushing Sprayer

Use only water-based or oil-based (mineral
spirit-type) materials with flash point greater than
100° F (38° C). Do not use materials which state
"FLAMMABLE" on the packaging. For more
information about your material, request MSDS
from distributor or retailer.
Use oil-based material outdoors or in a well-ventilated
indoor area with a flow of fresh air.
Keep spray area well-ventilated. Keep a good supply
of fresh air moving through the area.
NOTICE
Protect the internal parts of this sprayer from water.
Do not submerge the sprayer in cleaning fluid. Openings
in shroud allow cooling of mechanical parts and electron-
ics inside. If water gets into these openings, the sprayer
could malfunction or become permanently damaged.
1. Engage trigger lock and pull control lever UP to
release pressure.
ti14994a
2. Remove material cup and properly dispose cup liner
or excess material.
16
3. Remove and clean sprayer intake tube and screen
4. Clean cup if not using a liner, and fill with water or
5. Reconnect material cup and shake sprayer to move
ti14999a
6. Disengage trigger lock and trigger sprayer for
with water (or flushing fluid) and a brush every time
you flush the sprayer. Reconnect intake tube.
ti15002a
appropriate flushing fluid.
ti15001a
clean water around and clean all areas inside of
cup and underside of sprayer.
ti15441a
approximately 15 seconds. Engage trigger lock.
ti14994a