Shutdown And Cleaning; Pail Flushing - Graco MAGNUM Project Painter Plus Operation

Hide thumbs Also See for MAGNUM Project Painter Plus:
Table of Contents

Advertisement

Shutdown and Cleaning

Pail Flushing

For short term shutdown periods (overnight to two
days) refer to Short Term Storage, page 23.
For flushing after spraying oil-based coatings, use
compatible oil-based flushing fluid or mineral spirits.
Read Priming and Flushing Storage Fluid, page 12.
For flushing after spraying water-based coatings,
use water. Read Priming and Flushing Storage
Fluid, page 12 or Power Flush, page 20.
1. Relieve pressure, page 11.
2. Remove tip and guard assembly from gun and place
in flushing fluid.
3. Place empty waste and water or solvent pails side
by side.
WASTE
WATER or
SOLVENT
4. Lift suction tube and prime tube from paint pail. Let
them drain into paint pail for a while.
5. Separate prime tube (smaller) from suction tube
(larger).
ti2039a
18
ti9726a
6. Place prime tube in waste pail.
WASTE
7. Submerge suction tube in water or flushing solvent.
ti14963a
8. Turn pressure control knob to the Prime/Clean set-
ting.
9. Turn power switch ON.
ti5580a
10. Flush until approximately 1/3 of the flushing fluid is
emptied from the pail.
11. Turn power switch OFF.
ti2018a
Shutdown and Cleaning
ti14962a
WATER or
SOLVENT
ti12940a
332643B

Advertisement

Table of Contents
loading

This manual is also suitable for:

16w119

Table of Contents