Health Retry: No of Times Health Request will be sent, non response
of which will lead to Connection Expired.
Connection Timer: Time Interval, in seconds, after which a connection
request will be sent.
Connection Retry Count: No of Times Connection Request will be sent,
non response of which will lead to Init Mode.
Connection Wait Timer: Time Interval, in seconds, for which System
will wait after power on for Initialization of Network.
System Reboot
To Reboot or Restart System, click on System Reboot Link.
Reset ROIP to Factory Default Settings
Power On the ROIP.
Locate a press button at the bottom end of ROIP.
Press the button for 5-6 seconds while the ROIP is powered on, till
all led at the front panel blinks twice.
Reset Power of ROIP for changes to take effect.
15
Copyright 2017 @ Pulse Communication Systems Pvt. Ltd.
ROIP-400 Operation Manual