Troubleshooting - Pentair INTELLIWATER PNR-POE1-XTR3-01 Installation And Operation Manual

Table of Contents

Advertisement

TROUBLESHOOTING CONTINUED
Problem
Water conditioner
fails to regenerate.
Hard water.
Unit used too much salt.
Loss of water pressure.
Loss of mineral through drain line.
Iron in conditioned water.
Excessive water in brine tank.
Softener fails to draw brine.
Control cycles continuously.
Drain flows continuously.
20 • PENTAIR INTELLIWATER CONNECTED WATER SOFTENER
Cause
Electrical service to unit has been interrupted.
Controller is defective.
Power failure.
Bypass valve is open.
No salt is in the brine tank.
Injector screen plugged.
Insufficient water flowing into brine tank.
Hot water tank hardness.
Leak at distributor tube.
Internal valve leak.
Improper salt setting.
Excessive water in brine tank.
Iron buildup in line to water conditioner.
Iron buildup in water conditioner.
Inlet of control plugged due to foreign material broken
loose from pipes by recent work done on
plumbing system.
Air in water system.
Improperly sized drain line flow control.
Fouled mineral bed.
Plugged drain line flow control.
Plugged injector system.
Control not cycling.
Foreign material in brine valve.
Foreign material in brine line flow control.
Drain line flow control is plugged.
Injector is plugged.
Injector screen plugged.
Line pressure is too low.
Internal control leak.
Service adaptor did not cycle.
Misadjusted, broken, or shorted switch.
Powerhead is not completing the regen cycle.
Foreign material in control.
Internal control leak.
Correction
Assure permanent electrical service
(check fuse, plug, pull chain, or switch).
Replace controller.
Reset time of day.
Close bypass valve.
Add salt to brine tank and maintain salt
level above water level.
Clean injector screen.
Check brine tank fill time and clean brine line
flow control if plugged.
Repeated flushing of the hot water tank with
treated water is required.
Make sure distributor tube is not cracked.
Check o-ring and tube plot.
Replace seals and spacers and/or piston.
Check salt usage and salt setting.
See "Excessive water in brine tank".
Clean line to water conditioner.
Clean control and add mineral cleaner to mineral bed.
Increase frequency of regeneration.
Remove piston and clean control.
Assure that well system has proper air eliminator
control. Check for dry well condition.
Check for proper drain rate.
Check backwash, brine draw, and brine tank fill.
Increase frequency of regeneration, increase
backwash time.
Clean flow control.
Clean injector and screen.
Replace control.
Replace brine valve seat and clean valve.
Clean brine line flow control.
Clean drain line flow control.
Clean injector.
Clean screen.
Increase line pressure to 20 psi.
Change seals, spacers and piston assembly.
Check drive motor and switches.
Determine if switch or control is faulty and replace it,
or replace complete powerhead.
Check control positioning of valve. Replace powerhead
assembly if not positioning properly.
Remove powerhead assembly and inspect bore.
Remove foreign material and check control in various
regeneration positions.
Replace seals and piston assembly.