The pilot will resist lighting on new installations
due to air in the gas supply line. It may take
several minutes to bleed air completely out of the
gas plumbing system through the pilot line.
This appliance has a pilot which is lit by a spark
ignition device (piezo). If the piezo fails, then light
the pilot using matches following the Match Lighting
instructions below.
1. STOP! Read the safety information on page 13.
2. Push in gas control knob slightly and turn clock-
wise
to "OFF".
3. NOTE: Knob cannot be turned from "PILOT" to
"OFF" unless knob is pushed in slightly. Do
not force.
4. Wait five (5) minutes to clear out any gas. If you
then smell gas, STOP! Follow the safety informa-
tion above. If you don't smell gas, go on to the
f i r e - p a r t s . c o m
next step.
5. Turn the control knob counterclockwise
"PILOT" and push in. Continue to hold the control
knob in and push the piezo igniter button in until
the pilot lights.
6. Continue to hold the control knob in for about one
(1) minute after the pilot is lit. Release the knob
1. Follow the "Lighting the Pilot" instructions steps 1 thru 4 above.
2. Push the control dial in all the way and hold. Immediately light the pilot with a match. Continue to hold the
pilot for about one minute after the pilot is lit. Pilot should remain lit. If the pilot goes out, repeat Lighting
the pilot steps 1 thru 4 above and this step 2.
To Ignite The Appliance
With the pilot lit, turn the control dial counterclockwise
To Turn The Appliance Off
Push the control dial in slightly and turn clockwise
During the 2-3 hour appliance break-in period, you may detect an odor from the appliance as the various
water-based paints used in the manufacture of this log set cure. This is a normal and temporary situation that
is not a cause for alarm. However, you may want to provide extra ventilation to the room during this time.
Lighting The Pilot - SPKN/P
and it will pop back up. Pilot should remain lit. If it
goes out, repeat steps 3 and 4.
7. If the knob does not pop out when released, stop
and call your service technician or gas supplier. If
the pilot will not stay lit after several tries, turn the
gas control knob to "OFF' and call your service
technician or gas supplier.
8. Turn gas control knob counterclockwise
"ON". CAUTION: Be sure ON/OFF/RS switch is in
the off (middle) position. Also, the GWSK should
be in the "OFF" position and/or the remote should
be in the "OFF" position before turning the control
knob "ON". If pilot goes out, repeat steps 4 and 5.
10. Turn ON/
OFF/RS
switch to
"ON" or
remote
position.
Turn remote
switch to
to
"ON".
11. Flame is
adjustable by
rotating the
"HI/LO" knob.
Match Lighting

Igniting The Appliance

to ON.
to OFF. Do not force.

Appliance Break-in

14
PILOT
ON
OFF
ON
FROM "PILOT" POSITION
SLIGHT PUSH TO
TURN OFF
FULL PUSH TO
LIGHT
to
OFF

Advertisement

Table of Contents
loading

Table of Contents