ICMP-X

7.6 ICMP-X HDD status LEDs

ICMP-X HDD status LEDs

Image 7–9
4
HDD I/O LED
5
RAID LED
Status overview HDD I/Oand RAID LEDs:
HDD I/O
Off
Blinking green
Blinking green
Slow blinking
Blinking green
Fast blinking
Off
When entering a new HDD in an ICMP-X, the HDD RAID LED will be full red for a short time. This is
not an error, the HDD has not yet been "recognized" by the projector and ICMP-X.
Once the HDD has been accepted by the ICMP-X, the full red LED will start blinking in accordance
with the previous status table.
If the LED remains full red, an error has occurred. In this case, consult the following troubleshooting
table for curative actions.
Troubleshooting
Situation
One disk failed (red LED) + RAID degraded.
The ongoing event is not interrupted.
Note: The disk status (RAID degraded) can be
retrieved via the (Web) Commander. See user guide
of the (Web) Commander.
One disk failed (red LED) + Error 10580 "local
storage not available".
Note: The disk status (Error code) can be retrieved
via the (Web) Commander. See user guide of the
(Web) Commander.
82
R5913197 /02 SP2K-S
RAID
ICMP-X HDD Status
Off
HDD idle / disk in RAID OK.
Off
HDD I/O activity / disk in RAID OK.
HDD disks not (yet) initialized.
red
HDD I/O activity / RAID rebuilding.
red
Red
HDD idle / Disk error. Consult the following troubleshooting table for
curative actions.
Solution
1. Switch off the power.
2. Replace the defect HDD with approved model of
the same storage capacity. See procedure
"Removing a HDD from the ICMP-X", page
and
"Installing a HDD into the ICMP-X", page
Ensure to insert the HDD firmly.
3. Switch on the power.
Result: As soon the new HDD is detected by the
ICMP-X the rebuild of the RAID is started (Blinking
red LED).
1. Switch off the power.
2. Replace the defect HDD with approved model of
the same storage capacity. See procedure
"Removing a HDD from the ICMP-X", page
and
"Installing a HDD into the ICMP-X", page
Ensure to insert the HDD firmly.
3. Switch on the power.