Indications On The Display; Malfunctions - Bosch SMS6ECW07E User Manual

Table of Contents

Advertisement

Display instructions
Malfunction
Refill softening salt
indicator lights up.
Refill softening salt indicator
does not light up.
Rinse aid refill
indicator lights up.
Rinse aid refill indicator
does not light up.
Display flashes.

Malfunctions

Malfunction
Water remains in the
appliance at the end of the
programme.
Device cannot be
switched on or operated.
Cause
There is no softening
salt.
Sensor does not recognize
softening salt tablets.
Water softening is
switched off.
Rinse aid is missing.
Water softening is
switched off.
Appliance door is not
completely closed.
Cause
Sieve system or space under
the sieve is clogged.
Program has not yet
ended.
Software update in
progress.
Device functions
have failed.
TroubleshootingNL
Troubleshooting
Fill in "softening salt"→Page 25 Bee.
Do not use softening salt
tablets.
Set water softening
Fill the "rinse agent"
1.
Page 26Bee.
Set the amount of rinse aid.
2.
"Setting the rinse aid
amount", Page 27
Set the amount of rinse
aid.
Close the appliance door.
Arrange the crockery in such a
way that no crockery parts
protrude over the crockery
basket and prevent the
appliance door from closing
properly.
Troubleshooting
Clean the "seven"→Page 42.
1.
Clean the "drain pump"
2.
Page 59.
Wait for the end of the program or
cancel the program withReset off.
"Cancel program",
page 34
Wait for the software update to
complete.
Unplug the appliance from
1.
the mains or switch off the
fuse.
Wait at least 2 minutes.
2.