Overview Of Operation Setting - Panasonic MINAS A4P Series Instruction Manual

Panasonic ac servo motor and driver instruction manual
Table of Contents

Advertisement

Overview of Operation Setting

In MINAS A4P, the following operations can be performed.
Step operation
.....P.107
Jog operation
.....P.112
Homing operation
.....P.114
Emergency stop/
deceleration-and-stop
operation
.....P.125
Temporary stop operation
.....P.126
Block operation
.....P.127
Sequential operation
.....P.130
S-shaped acceleration/
deceleration operation
.....P.131
<Notice>
• For how to set a step data or parameters, "Hot To Use Console" on page 80.
• When setting the step parameters using "PANATERM
deceleration = D1 to D4 are shown. This instruction manual describes speed = VEL1 to VEL16, decelera-
tion = ACC1 to ACC4 and deceleration = DEC1 to DEC4.
106
The most basic operation.
Specify a point number set in advance when performing the operation.
The four types of modes are available, i.e., an incremental operation,
absolute operation, rotary axis operation and dwell timer (waiting time).
The motor can be moved in a positive direction or negative direction
independently.
This is useful for teaching or adjustment.
An operation to detect a home position which is the base of operation.
The eight types of homing operations can be performed in A4P.
Homing must be completed before performing the step operation etc.
Also, homing can be disabled by setting a certain parameter.
An active operation can be interrupted and canceled.
Emergency stop: An operation stops in a deceleration time specified by a
special parameter.
Deceleration-and-stop: An operation stops in a deceleration time specified
in an operation mode before the start of deceleration.
Active operation can be stopped temporarily and restarted.
Several step operations can be performed at a time. The two types of block
operations below can be executed.
Continuous block operation: Several step operations can be performed
continuously. Once an operation starts, the operation continues to a
specified point number.
Combined block operation: A step operation is performed according to
combined several point numbers. This is useful when you want to change
the speed during a step operation.
A point number increments by 1 automatically whenever an operation
command is given.
A step operation can be performed easily only by turning the STB signal
on/off.
An operation can be performed smoothly by executing the start and end of
acceleration/deceleration gradually.
®
", speed = V1 to V6, deceleration = A1 to A4 and