E020-1260 Displays Because The Dustproof Shutter Is Not Open; E020-0360 Occurs Due To An Installation Error Of The Bk Hopper Unit - Canon imageRUNNER ADVANCE C2000 Series Technical Workbook

Table of Contents

Advertisement

Title

E020-1260 displays because the Dustproof Shutter is not open

Symptom
E020-1260 displays while the machine is being installed.
- E020-1260: Abnormal detected patch reading value
Cause
Foreign substance [B] is mixed into the Dustproof Shutter [A] of cyan Laser Scanner Unit, and this prevents
the shutter from opening fully. [C] indicates the range of open/close shutter.
Service work
Check the Dustproof Shutter. Remove the foreign substances if you find any.
Title

E020-0360 occurs due to an installation error of the Bk hopper unit

Symptom
E020-0360 occurred a few days after the replacement of the Bk hopper unit.
- E020-0360: Low density for the target at patch detection
pg. 72