SiBE06-708_A
3.7

Removal of Four Way Valve

Procedure
Step
Pull out the electronic
1
expansion valve coil.
Remove the terminal
2
cover.
Disconnect the lead
3
wires of the
compressor.
Removal Procedure
Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Red (U)
Yellow (V)
Blue (W)
Electronic
expansion
valve coil
(R7233)
Terminal cover
(R7234)
(R7235)
Outdoor Unit - RK(X)S25/35G2V1B
Points
198