SiBE06-708_A
1.5
Removal of Vertical Blades
Procedure
Step
1. Remove the vertical blade
(upper).
Remove the 2 screws
1
and remove the air
outlet ASSY.
2
The air outlet ASSY
has the 2 vertical
blades ASSYs.
3
Unfasten the 2 hooks
and the center hook to
remove the vertical
blades ASSY.
4
Slide the protection net
along the right and the
left grooves and
remove it.
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Air outlet ASSY
Screw
Vertical blades ASSY
Center hook
Hooks
Protection net
Groove
Screw
(R6803)
(R6804)
(R6805)
(R6806)
Indoor Unit
Points
148