SiBE06-708_A
1.2

Heat Pump

Indoor Units
Model
Outdoor Units
Capacity
Rated (Min. ~ Max.)
Moisture Removal
Running Current Rated
Power Consumption
Rated (Min. ~ Max.)
Power Factor
COP
Rated (Min. ~ Max.)
Liquid
Piping
Gas
Connections
Drain
Heat Insulation
Max. Interunit Piping Length
Max. Interunit Height Difference
Chargeless
Amount of Additional Charge of
Refrigerant
Indoor Unit
Front Panel Color
m³/min
Airflow Rate
(cfm)
Type
Fan
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (H × W × D)
Packaged Dimensions (H × W × D)
Weight
Gross Weight
Operation
H / M / L / SL
Sound
Sound Power
Outdoor Unit
Casing Color
Type
Compressor
Model
Motor Output
Type
Refrigerant
Oil
Charge
Type
Refrigerant
Charge
Airflow Rate
m³/min (cfm)
Type
Fan
Motor Output
Running Current (Rated)
Power Consumption (Rated)
Power Factor (Rated)
Starting Current
Dimensions (H × W × D)
Packaged Dimensions (H × W × D)
Weight
Gross Weight
Operation
H / L
Sound
Sound Power H
Drawing No.
Note:
Specifications
Cooling
kW
2.5 (1.3 ~ 3.0)
Btu/h
8,500 (4,400 ~ 10,200)
kcal/h
2,150 (1,120 ~ 2,580)
L/h
1.2
A
3.5 - 3.3 - 3.2
W
570 (300 ~ 920)
%
74.0 - 75.1 - 74.2
W/W
4.39
mm
mm
mm
Both Liquid and Gas Pipes
m
m
m
g/m
H
8.2 (290)
M
6.5 (229)
L
4.8 (169)
SL
4.1 (146)
W
Steps
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable / Washable / Mildew Proof
A
0.14 - 0.13 - 0.12
W
15
%
48.7 - 50.2 - 52.1
Microcomputer Control
mm
600 × 700 × 210
mm
696 × 786 × 286
kg
kg
dBA
38 / 32 / 26 / 23
dBA
54
Hermetically Sealed Swing Type
W
L
kg
H
33.5 (1,183)
L
23.4 (826)
W
A
3.4 - 3.2 - 3.1
W
555
%
74.2 - 75.4 - 74.6
A
mm
550 × 765 × 285
mm
612 × 906 × 364
kg
kg
dBA
46 / 43
dBA
61
The data are based on the conditions shown in the table below.
Cooling
Indoor ; 27°CDB / 19°CWB
Outdoor ; 35°CDB / 24°CWB
SL : The quiet fan level of the airflow rate setting.
FVXS25FV1B
RXS25F2V1B
Heating
3.4 (1.3 ~ 4.5)
11,600 (4,400 ~ 17,100)
2,920 (1,120 ~ 4,300)
4.5 - 4.3 - 4.1
790 (290 ~ 1,390)
79.8 - 79.9 - 80.3
4.30
φ
6.4
φ
9.5
φ
20
20
15
10
20
FVXS25FV1B
White
8.8 (311)
6.9 (244)
5.0 (178)
4.4 (155)
Turbo Fan
48
0.15 - 0.14 - 0.13
17
51.5 - 52.8 - 54.5
14
18
38 / 32 / 26 / 23
54
RXS25F2V1B
Ivory White
1YC23NXD
600
FVC50K
0.375
R-410A
1.0
30.2 (1,066)
28.3 (999)
Propeller
23
4.4 - 4.2 - 4.0
773
80.3 - 80.0 - 80.5
4.5
34
40
47 / 44
62
3D056274A
Piping Length
7.5 m
Specifications
50 Hz, 220 - 230 - 240 V
FVXS35FV1B
RXS35F2V1B
Cooling
3.5 (1.4 ~ 3.8)
4.5 (1.4 ~ 5.0)
11,900 (4,800 ~ 13,000)
15,400 (4,800 ~ 17,100)
3,010 (1,200 ~ 3,270)
3,870 (1,200 ~ 4,300)
1.9
4.9 - 4.7 - 4.5
5.9 - 5.6 - 5.4
1,020 (300 ~ 1,250)
1,220 (310 ~ 1,880)
94.6 - 94.4 - 94.4
94.0 - 94.7 - 94.1
3.43
φ
6.4
φ
9.5
φ
20
Both Liquid and Gas Pipes
20
15
10
20
FVXS35FV1B
White
8.5 (300)
6.7 (237)
4.9 (174)
4.5 (158)
Turbo Fan
48
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable / Washable / Mildew Proof
0.14 - 0.13 - 0.12
0.15 - 0.14 - 0.13
15
48.7 - 50.2 - 52.1
51.5 - 52.8 - 54.5
Microcomputer Control
600 × 700 × 210
696 × 786 × 286
14
18
39 / 33 / 27 / 24
39 / 33 / 27 / 24
55
RXS35F2V1B
Ivory White
Hermetically Sealed Swing Type
1YC23NXD
600
FVC50K
0.375
R-410A
1.0
33.5 (1,183)
30.2 (1,066)
23.4 (826)
Propeller
23
4.8 - 4.6 - 4.4
5.8 - 5.5 - 5.3
1,005
95.1 - 95.0 - 95.1
94.3 - 95.1 - 94.6
5.9
550 × 765 × 285
612 × 906 × 364
34
40
47 / 44
62
3D056275A
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
Heating
3.69
9.4 (332)
7.3 (258)
5.2 (184)
4.7 (168)
17
55
28.3 (999)
1,203
48 / 45
63
14

Hide quick links: