Specifications; Cooling Only - Daikin Floor Standing Type F-Series Service Manual

Inverter pair
Table of Contents

Advertisement

Specifications

1. Specifications

1.1 Cooling Only

Indoor Units
Model
Outdoor Units
Capacity
Rated (Min. ~ Max.)
Moisture Removal
Running Current (Rated)
Power Consumption
Rated (Min. ~ Max.)
Power Factor
COP (Rated)
Liquid
Piping
Gas
Connections
Drain
Heat Insulation
Max. Interunit Piping Length
Max. Interunit Height Difference
Chargeless
Amount of Additional Charge of
Refrigerant
Indoor Unit
Front Panel Color
m³/min
Airflow Rate
(cfm)
Type
Fan
Motor Output
Speed
Air Direction Control
Air Filter
Running Current
Power Consumption
Power Factor
Temperature Control
Dimensions (H × W × D)
Packaged Dimensions (H × W × D)
Weight
Gross Weight
Operation
H / M / L / SL
Sound
Sound Power
Outdoor Unit
Casing Color
Type
Compressor
Model
Motor Output
Type
Refrigerant
Oil
Charge
Type
Refrigerant
Charge
Airflow Rate
m³/min (cfm)
Type
Fan
Motor Output
Running Current
Power Consumption
Power Factor
Starting Current
Dimensions (H × W × D)
Packaged Dimensions (H × W × D)
Weight
Gross Weight
Operation
H / L
Sound
Sound Power H
Drawing No.
Note:
9
kW
Btu/h
8,500 (4,400 ~ 10,200)
kcal/h
2,150 (1,120 ~ 2,580)
L/h
A
W
%
74.0 - 75.1 - 74.2
W/W
mm
mm
mm
Both Liquid and Gas Pipes
m
m
m
g/m
H
M
L
SL
W
Steps
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable / Washable / Mildew Proof
A
0.14 - 0.13 - 0.12
W
%
48.7 - 50.2 - 52.1
Microcomputer Control
mm
600 × 700 × 210
mm
696 × 786 × 286
kg
kg
dBA
dBA
Hermetically Sealed Swing Type
W
L
kg
H
L
W
A
W
%
74.2 - 75.4 - 74.6
A
mm
550 × 765 × 285
mm
612 × 906 × 364
kg
kg
dBA
dBA
The data are based on the conditions shown in the table below.
Cooling
Indoor ; 27°CDB / 19°CWB
Outdoor ; 35°CDB / 24°CWB
SL : The quiet fan level of the airflow rate setting.
FVXS25FV1B
RKS25F2V1B
2.5 (1.3 ~ 3.0)
1.2
3.5 - 3.3 - 3.2
570 (300 ~ 920)
4.39
φ
6.4
φ
9.5
φ
20.0
20
15
10
20
FVXS25FV1B
White
8.2 (290)
6.5 (229)
4.8 (169)
4.1 (146)
Turbo Fan
48
15
14
18
38 / 32 / 26 / 23
54
RKS25F2V1B
Ivory White
1YC23NXD
600
FVC50K
0.375
R-410A
1.0
33.5 (1,183)
23.4 (826)
Propeller
23
3.4 - 3.2 - 3.1
555
3.5
34
40
46 / 43
61
3D056295A
Piping Length
7.5 m
SiBE06-708_A
50 Hz, 220 - 230 - 240 V
FVXS35FV1B
RKS35F2V1B
3.5 (1.4 ~ 3.8)
11,900 (4,800 ~ 13,000)
3,010 (1,200 ~ 3,270)
1.9
4.9 - 4.7 - 4.5
1,020 (300 ~ 1,250)
94.6 - 94.4 - 94.4
3.43
φ
6.4
φ
9.5
φ
20.0
Both Liquid and Gas Pipes
20
15
10
20
FVXS35FV1B
White
8.5 (300)
6.7 (237)
4.9 (174)
4.5 (158)
Turbo Fan
48
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable / Washable / Mildew Proof
0.14 - 0.13 - 0.12
15
48.7 - 50.2 - 52.1
Microcomputer Control
600 × 700 × 210
696 × 786 × 286
14
18
39 / 33 / 27 / 24
55
RKS35F2V1B
Ivory White
Hermetically Sealed Swing Type
1YC23NXD
600
FVC50K
0.375
R-410A
1.0
33.5 (1,183)
23.4 (826)
Propeller
23
4.8 - 4.6 - 4.4
1,005
95.1 - 95.0 - 95.1
4.9
550 × 765 × 285
612 × 906 × 364
34
40
47 / 44
62
3D056296A
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
Specifications

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents