Settings For A Heated Swimming Pool; Additional Device (Auxiliary Heater) Settings - Bosch HPC 400 Operating Instructions Manual

User interface
Table of Contents

Advertisement

Operating the appliance
▶ Turn the selector to highlight Own time program and press the selector.
The time program for circulation is independent of the time program for DHW heating.
The switching times can be set separately in the Circulation > My DHW circltn time
prog. menu (operation as described in Chapter 5.2.2 starting on page 15). The
circulation is either switched on or off in the respective time slots.
▶ Turn the selector to highlight off or on and press the selector.
The user interface operates with the modified settings. The DHW circulation pump is
always off in the phases with off.
Table 24 Adapting circulation settings
5.4

Settings for a heated swimming pool

This menu is used to adapt the settings that are available for a
heated swimming pool.
Menu: Pool
Menu item
description
Activate pool
The swimming pool is heated when the pool
heating
heating system is switched on.
Pool
The water in the swimming pool is heated to
temperature
the temperature set here.
Allow
If the auxiliary heater has been approved for
additional
use with the swimming pool, the required
heat in pool
water temperature can also be reached
mode
using the auxiliary heater even if the heat
pump does not supply enough heat.
Table 25 Swimming pool settings
5.5

Additional device (auxiliary heater) settings

If the heat pump does not supply enough heat quickly enough in
winter or for DHW heating, an additional device (an auxiliary
heater) may be required. There is the option to use an electric
booster heater or an additional device (gas, oil or wood heating
via a 3-way valve).
This menu is only available if an auxiliary heater is installed in
the heating system.
HPC 400
CLIMATE CONTROL SYSTEMS
5.5.1 Time program for the additional device
If you are not at home or a lower room temperature is sufficient
for other reasons, it is possible to lower energy consumption by
limiting the operation of the auxiliary heater.
Menu: Device > Time program additional heat
Menu item description
Time
program
Activate
additional
heat
My time
program
Reset time
program
Time
program
min.
outdoor
temp.
Table 26 Time program for an additional device
VOGEL
NOOT
&
Working with the main menu | 23
Result
When the time program for the auxiliary heater
has been activated, the auxiliary heater is only
able to deliver additional heat in the phases
with the on operating mode.
The time program for the auxiliary heater can
be set under this menu item.
The time program for the auxiliary heater is
reset to the default settings.
If the outside temperature falls below the
temperature set here, the auxiliary heater time
program is switched off. The auxiliary heater is
in operation.
6 720 817 986 (2015/07)
6 720 815 237-44.1O

Hide quick links:

Advertisement

Table of Contents
loading