Operating the appliance
Calling up the outside temperature profile
▶ If the standard display is active, press the info key to open the info menu.
▶ Turn the selector to highlight Outside temperature and press the selector.
▶ Press the selector.
The diagram shows the outside temperature profile for the last 2 days (more detailed
information,  Chapter 6, page 32).
Table 45 Calling up information about the outside temperature
Menu: Internet
This menu is only available if at least one communication
module is installed.
Menu item
description
IP connection
Status of the connection between
communication module and router
Server connection Status of the connection between
communication module and Internet
(via the router)
SW version
Software version of the
communication module
Login data
Login name and password for the login
into the App to operate the system via
a smartphone
MAC address
Communication module MAC address
Table 46 Information about the Internet connection
Menu: System information
Information is only displayed under the individual menu items if
the corresponding parts of the system are installed. If 2 heat
pumps are installed, you will need to choose between heat
pump 1 and heat pump 2.
Menu item
description
Heat pump
A range of information on the status of the
status
heat pump is available here.
The outdoor unit is either off or in
Cooling circuit
operation for various purposes. This menu
status
item issues the following operating
conditions: Off; Heating; Cooling; DHW;
Pool; Pool/heating; Defrosting; Alarm
Compressor
The output produced by the compressor in
output
kW (0.1 ... 15.0)
Table 47 System information
HPC 400
CLIMATE CONTROL SYSTEMS
Menu item
Status
additional heat
Elec. add
heater output
Status mixed
additional heat
El. DHW
additional
heater
Electricity
company
1)
block
PV
Smart grid
Actual mode
Table 47 System information
1) The energy supplier block is not normally used in Sweden.
VOGEL
NOOT
&
Calling up information about the system | 35
Result
description
The auxiliary heater is either off or in
operation for various purposes. This menu
item issues the following operating
conditions: Off; Heating; Cooling; DHW;
Pool; Pool/heating; Alarm
The output produced by the auxiliary
heater in kW (0.1 ... 15.0)
Add. heat source: Auxiliary heater is
On or Off.
Mixing valve: If the heat pump output
is not sufficient temporarily, hot
heating water is mixed with the heating
water from the heat pump via a mixer.
In such cases: 0% = no additional
heating provided ... 100% = maximum
level of additional output is provided.
The DHW auxiliary heater is On or Off.
If On is displayed here, the system
operates with restricted electrical output.
If Off is displayed here, the system can
operate with full electrical output.
If On is displayed here, a PV system
(photovoltaic system) supplies the heat
pump with energy. If Off is displayed here,
no energy is available from the PV system.
The currently valid signal sent by the
energy supplier for the use of the "smart
grid" is displayed here (status 2/status 3/
status 4).
Currently valid operating mode in the
selected heating circuit (Heating, Idle,
Cooling)
6 720 817 986 (2015/07)