Operation - Crown GLT-80 Installation & Operation Manual

Gas fired steam tilting
Table of Contents

Advertisement

Gas Fired Steam Tilting Kettles

Operation

Contact the factory, the factory representative or a local service company to perform maintenance and repairs
should the appliance malfunction.
In the event you smell gas, shut down equipment at the main shut off valve and contact the
In the event of main burner ignition failure, a 5 minute purge period must be observed prior
If you smell gas during the lighting procedure, immediately shut off the gas supply until the leak has been corrected.
Gas Control Instructions
Appliance does not require "Lighting" the pilot with a flame.
Start-Up
1. Turn thermostat to "OFF" position and main power switch to "OFF" position.
2. Open control panel access door located on right side at bottom.
3. Turn dial on gas combination control valve to "ON" position by rotating control knob counterclockwise. (NOTE: Any
gas service valves exterior to the unit should be open.)
4. Turn main power switch to "ON" position.
5. Set "COOK TEMP" to desired setting. The red "COOKING" pilot will be on until desired setting has been reached.
6. At this time the spark igniter will begin sparking at the pilot until the pilot is ignited, or for ninety seconds (an audible
clicking sound will be evident).
7. When the pilot is ignited the spark igniter will automatically stop and within 15 seconds main burner gas will come on.
If ignition does not occur, after a total of ninety seconds, the unit will lockout, shutting off all gas although the spark
igniter will continue to spark. New installations (where there may be a considerable amount of air in the gas line) may
require the unit to be turned off and immediately back on numerous times after each lockout period until the air is
purged from the gas line.
Shutdown
A. Standby
1. Place main power switch and thermostat to "OFF" position.
INSTALLATION & OPERATION MANUAL 10325 REV 1 (11/21)
NOTICE
WARNING
local gas company or gas supplier for service.
WARNING
to re-establishing ignition source.
CAUTION
O
PERATION
9
PAGE
OF32