Operation Instructions - Crown EL-20F Installation & Operation Manual

Self generating steam full jacket kettles
Table of Contents

Advertisement

INSTALLATION AND OPERATION MANUAL, SELF-GENERATING STEAM FULL JACKETED
KETTLES, MODELS EL-20F TO EL-60F, EP-20F TO EP-60F

6.0 OPERATION INSTRUCTIONS

WARNING: The kettle and its parts are hot. Use care when
operating, cleaning and servicing the kettle.
Ensure that the external electrical service to kettle is on.
Check pressure gauge for correct cold kettle reading. Reading should be in the green area of
the gauge indicating 25 - 30 In. Hg (630 - 730 mm Hg) of vacuum. If reading is not low enough,
follow VENTING procedure in Troubleshooting section prior to using kettle.
Place power switch to ON position.
Preheat kettle by placing thermostat knob at '10' and wait until TEMPERATURE light goes off.
NOTE: Preheating should not be used when cooking milk and egg food
products which adhere to hot cooking surfaces. These foods should be placed
into kettle before heating has begun.
Add food to be cooked into kettle.
Place thermostat knob at required temperature setting from 1 to 10 coinciding with the following
table:
THERMOSTAT SETTING
1
2
3
4
5
6
7
8
9
10
PART NO. 10168R2
APPROXIMATE (JACKET) TEMPERATURE
140° Fahrenheit
155° Fahrenheit
172° Fahrenheit
187° Fahrenheit
205° Fahrenheit
223° Fahrenheit
240° Fahrenheit
255° Fahrenheit
271° Fahrenheit
285° Fahrenheit
10
60°Celsius
68°Celsius
78° Celsius
86 °Celsius
96° Celsius
106° Celsius
116° Celsius
124° Celsius
133° Celsius
140° Celsius
2013-07-17

Advertisement

Table of Contents
loading

This manual is also suitable for:

El-30fEl-40fEl-60fEp-20fEp-30fEp-40f ... Show all

Table of Contents