Replacing Condenser Motor - Hussmann FNGSC-A Installation & Operation Manual

Dual temperature self contained island merchandiser
Table of Contents

Advertisement

P/N 3141959_C

REPLACING CONDENSER MOTOR

Unplug the power cords before servicing.
Parts may be ordered at Hussmann's Performance
Parts e-store:
https://parts.hussmann.com/
or
Call toll free: 855-487-7778
Required Tools:
• Screwdriver / Philips Tip
• 1/4" Allen Wrench
1 . Remove product and place in a refrigerated
area . Make sure the power is off to the
case .
2 . Make sure there is no voltage in the
refrigerator . Remove rear lower panel as
shown in the illustration .
3 . Slide out the condensing unit . Be careful
using the condensing unit base to pull it
NOTES:
out . Make sure not to stress or interfere
1. APPLICABLE STANDARDS / SPECIFICATIONS
ASME Y14.5M-1994, DIMENSIONS AND TOLERANCES
2. KEY PRODUCT CHARACTERISTICS PER EPR-0006 & IDENTIFIED WITH SYMBOL
3. MATERIAL-
with other parts .
4. REF
FNGSC4A
FNGSC4 Shown
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
FNGSC6A
4 . Disconnect condenser motor harness .
5 . If a flexible extension is used, skip Step 6 .
6 . Release screws to partially remove venturi
assembly .
FNGSC6 Shown
FNGSC6A COND UNIT
7 . Release screws to remove condenser fan
assembly .
NOTES APPLICABLE UNLESS OTHERWISE SPECIFIED
DO NOT SCALE - DIMENSIONS TO OUTSIDE UNLESS OTHERWISE NOTED
PART TO BE FREE OF BURRS, SHARP EDGES, AND CORNERS
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
DECIMALS .XX
.03, .XXX
u
ANGLES
PROJECTION
SHEET 3 OF 5
8 . Release motor screws to get to motor /
blade assembly .
9 . Change failed part .
10 . If the only damaged part is the motor,
remove blade .
11 . Reverse the process and make sure
everything is in place and working .
FNGSC-A Self Contained Merchandisers
FNGSC4 Shown
R
.010
u
u
2
v
THIRD
ANGLE
REV
P/N
5-3

Advertisement

Table of Contents
loading

Table of Contents