Seal Merchandisers; Install Splashguard Brackets; Replacing Interior Panels And Discharge; Air Louvers - Hussmann BEXDWG Installation & Operation Manual

Low temperature
Table of Contents

Advertisement

I
1-10
nstallatIon

Seal Merchandisers

1. Remove wire rack, rack supports and
interior panels to apply butyl tape.
2. Apply butyl tape across the bottom joint.
Be sure to extend the tape up the back and
front of the merchandiser.
Silicone sealer may be applied around joining
bolts on both sides in bottom shoe.
INSTALLING SPLASHGUARD
BRACKETS
Position splashguard brackets to the
merchandiser and level to the floor. Each
bracket has a 1
/
 in. (38 mm) slot at the
1
2
Splashguard
rear of the bracket where it attaches to the
Bracket
merchandiser. Tighten screws to secure the
Leg
Screw
brackets.
Important: Install splashguard brackets before
installing drip piping.
REPLACING INTERIOR PANELS AND
DISCHARGE AIR LOUVERS
After case joining is complete and all joining
bolts are fastened, re-install the interior front
and back panels. Special care needs to be taken
when re-installing the discharge air louvers. The
flange at the top of the louver must properly
fit into the correct position in the extrusion.
DETAIL
Incorrect position of the louver can cause
the plastic nosing on the anti-sweat heater to
become dislodged. See details in Section 6 for
Anti-Sweat Heater
Plastic Nosing
correct steps to re-install plastic nosing extrusion.
Discharge Air Louver
Louver Retainer
Retainer Fastener
P/N 3093114_A