2-5.
HIGH TEMPERATURE
LIMIT (Continued)
2-6.

HEATING ELEMENTS

593
15. With excess capillary tube pulled out, tighten smaller nut.
Do not overtighten nut or damage to capillary tube may
result.
16. Replace front panel.
17. Refill with shortening.
Heating elements are available for 208 and 480 voltage.
Check the data plate to determine the correct voltage.
If the shortening's temperature recovery is very slow or at a slower
rate than required, this may indicate defective heating element(s). An
ohmmeter will quickly indicate if the elements are shorted or open.
To avoid electrical shock or property damage, move the
power switch to "OFF" and disconnect main circuit breaker,
or unplug cord at wall receptacle.
1. Remove the control panel. Refer to Section 2-3.
2. Perform an ohm check on one element at a time, with wires
disconnected from element. If the resistance is not within toler-
ance, replace the element.
Voltage
480
415
380
240
208
480
415
240
208
SHOCK HAZARD
Resistance
Wattage
in Ohms (Cold)
7333
7333
7333
7333
7333
4500
4500
11.75
4500
11.75
4500
Model OE-100
27.5
6.9
18.8
6.9
5.6
51.2
9.61
2-5