This section provides troubleshooting information in the form of
an easy-to-read table.
If a problem occurs during the first operation of a new fryer,
recheck the installation per Section 2 of this manual.
Before troubleshooting, always recheck the operating procedure
per Section 3 of this manual.
e T
LES
In the event of a control system failure, the digital display will
show an "Error Message." These messages are coded: E5, E4, E6,
ElO, E15, E41, E50, E51, and E53.
en turn switc
display shows E4, the control board is getting too hot. Check the
louvers on each side of the unit for obstuctions. If E4 persists,
Turn switch to OFF position, then turn switch back to ON. If
display shows E6, thermal sensor must be replaced. Refer to
section 6-4.
button. If high limit does not reset, high limit must be replaced
per section 6-5, or 6-6.
El5
E41, E50,
E5 1, E53
Drain Switch
Close drain, using the drain valve handle. If display still shows
Failure
E 15 check drain valve section 6- 13.
Programming
Turn switch to OFF, then back to ON. If display shows any of
Failure
the error codes, the control panel needs replaced.

Advertisement

loading

Summary of Contents for Henny Penny OE/OG 301/302/303

  • Page 1 This section provides troubleshooting information in the form of an easy-to-read table. If a problem occurs during the first operation of a new fryer, recheck the installation per Section 2 of this manual. Before troubleshooting, always recheck the operating procedure per Section 3 of this manual.
  • Page 2 Open Circuit With switch in POWER position and switch light not illuminated, fryer is complete ly inoperative. No power to With switch in power position, board switch light is on, but all other lights are out ex cept the pump will operate.
  • Page 3 Replace therm0 couple per Section 6-10. Service per Section 6-11. Close drain valve. With power removed from fryer, check across high limit switch terminals with ohmmeter. Replace if no reading is indicated on meter. With power removed from fryer, check across electrical leads of gas control valve with ohmmeter, and gas valve in “ON”...
  • Page 4 5-2. T (Continued) Low or improper Heating of shortening too voltage (elec. slow model) Weak or burnt out elements (elec. model) Heating of Points in contac- tor bad (elec. shortening too slow (elec. model model) Wire(s) loose Burnt or charred wire connection Supply line too small - low gas...
  • Page 5 Water in ing over of shortening shortening. Improper or bad shortening Improper filtering Improper rinsing after cleaning the fryer Drain valve Shortening will not drain from clogged with frypot crumbs Drain valve will not open by turn- ing handle Filter motor rum...