Heating Elements - Henny Penny 581 Service Manual

Pressure fryer
Hide thumbs Also See for 581:
Table of Contents

Advertisement

Heating of
shortening too
slow (Electric
Model)
Shortening
overheating
(Electric Model)
Foaming or boil-
ing o,ver of
shortening
Low or improper voltage.
Weak or burnt out
element(s).
Points in contactor bad.
Wire(s) loose.
Burnt or charred wire
connection.
Check shortening
temperature.
Check contactor for not
opening.
Faulty PC Board.
Faulty probe.
Use a meter and check the
receptacle against data
plate.
Check heating element(s)
per Maintenance Section on
Heating Elements.
Check contactor per
Maintenance Section on
Contactors.
Tighten.
Replace wire and clean
connectors.
Check temperature setting
in the program mode.
Check faulty contactor per
Maintenance Section on
Contactors.
Remove and replace control
panel.
Remove and replace probe.
Water in shortening.
Condensation line stopped
up.
Improper or bad
shortening.
Improper filtering.
At end of cooking cycle,
drain shortening and clean
cookpot. Add fresh
shortening.
Remove and clean conden-
sation line.
Use recommended
shortening.
Refer to the procedure
covering filtering the
shortening.

Advertisement