BMW Wallbox Instructions For Use Manual page 63

Hide thumbs Also See for Wallbox:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 44
7.2 Phase assignment
The phase assignment between the Wallbox and household connection can be set using DIP
switches.
The phase assignment between the Wallbox and household connection/meter can be set using DIP
switches 2 and 3
DIP switch setting
00
01
62
Phase assignment
household
connection/meter
-> Wallbox
L1 -> L1
L2 -> L2
L3 -> L3
L2 -> L1
L3 -> L2
L1 -> L3
Configuration
10
Phase assignment
household
connection/meter
-> Wallbox
L3 -> L1
L1 -> L2
L2 -> L3

Hide quick links: