Normal Operating Odors

This appliance has several areas that reach high temperatures. Dust or other particles in these areas
may burn and create an odor. This is normal during start-up. You may notice the smell is more acute if
the appliance was left idle for a long period.

Power Outages

Four AA batteries are used as a power backup for the fireplace in case the household (AC) power goes out. These
batteries must be inserted into battery holder (or remove receiver is using the optional GS thermostatic remote). The
fireplace controller will beep once these batteries start to go dead. Replace batteries before each heating season to
ensure proper operation.
The light and blower will not operate.

Glass Frame Removal and Installation

A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this
appliance and shall be installed for the protection of children and other at-risk individuals.
If the barrier becomes damaged, the barrier shall be replaced with the manufacturer's barrier for
this appliance.
The appliance must be completely cool before removing the glass.
Do not strike or slam the glass.
Warning: Do not operate appliance with the glass front removed, cracked, or broken.
Replacement of the glass should be done by a licensed or qualified service person.
Remove the screen-trim assembly by lifting the assembly up slightly and tilting it toward you. The
mounting hooks on the back of the assembly will disengage the fireplace. Set the assembly
aside for reinstallation.
NOTE: Opening the access door on the front of the assembly allows for an easy location to get a secure
grip on the assembly for removal