Download Print this page

Master FFLS325 Operation Manual page 30

Laser screed

Advertisement

2. Need to change the engine oil, every 100 hours working time.
IX. The common failures and solutions
I.
The Emitter cannot be started
Reason: :out of power。
Solution:Change the new battery.
3. Emitter discontinuous, intermittent emission light beam
Reason:The machine transmitter with automatically leveling, if the
tripod is not stable, with the shake that make the emitter shake,
will lead the emitter leveling again and again,
and that is level, meanwhile it is not a laser beam during the leveling
launcher. The following three conditions is the main cause of the
above problem:
①.Check the ground(or other surface) if stable or not, have
any shake or vibration.
②.The damage of the tripod, the fixed surface of the emitter
is not level.
③.the big wind and other reason, make the tripod or the
rock or the Emitter rocking
Solution:①Move the Emitter to the level off and not rock ground;
②Change the tripod;
③Find the shelter place, or add some weight on the
tripod to prevent the rock.
3 .The edge of the concrete floor is leakiness.
Reason:The floor edge commonly with the template, the machine
can not leveling well of the edge and corner.
Tel:(+86)17737606271
26
Henan Master Machinery Co., Ltd
www.mastermachinerys.com

Advertisement

loading