6.
press the stop button to stop the machine.
allow the spindle to stop rotating before pro-
ceeding.
7.
repeat step 5 with the reverse button.
the spindle should rotate in the opposite
direction.
8.
press the eMergenCy stop button to
stop the machine. allow the spindle to stop
rotating before proceeding.
9.
Without resetting the switch, press the
ForWard button. the machine should not
start.
—if the machine does not start, the
eMergenCy stop button safety feature
is working correctly. the test run is com-
plete.
—if the machine does start (with the stop
button pushed in), immediately disconnect
power to the machine. the oFF button
safety feature is not working correctly. this
safety feature must work properly before
proceeding with regular operations. Call
tech support for help.
-24-

break-in

NOTICE
failure to follow spindle break-in proce-
dures will likely cause rapid deterioration of
the spindle and other related parts and may
void the warranty.
NOTICE
do not leave the area while break-in pro-
cedure is under way. you must be ready to
stop the machine if any problem occurs.
it is essential to closely follow the proper break-in
procedures to ensure trouble free performance.
Complete this process once you have familiarized
yourself with all instructions in this manual.
to break in the spindle:
1.
Make sure the machine has been properly
lubricated. refer to lubrication on page
39.
2.
Make sure the spindle area is free of obstruc-
tions.
3.
set the spindle speed to the lowest rpM.
refer to speed changes on page 29.
4.
turn the spindle ON and let it run for a mini-
mum of 10 minutes. repeat this step for each
rpM setting. refer to speed changes on
page 29.