6. Remove pilot hood, then use allen key to remove pilot orifice.
Figure 13.e Removing the pilot hood, orifice
7. Insert Propane pilot orifice. Reassemble burner assembly.
Figure 13.f Insert propane orifice, reassemble burner
8. The pilot size can be adjusted using a flathead screwdriver to
adjust "pilADJ" screw shown
Figure 13.g Adjust pilot size
24
9. The manifold and inlet pressure can be verified by using a
manometer and a 1/8" rubber hose attached to the valve
ports shown here (top is manifold, bottom is inlet)
Figure 13.h Adjust pressure ports
10. Use a soap-based leak testing solution on the valve regulator
while the unit is operating to check for any leaks
11. Fill out required information on Propane conversion gas fitter
sign off label, attach to reverse side of rating plate. Attach
Rating plate conversion label to rating plate label. Place Valve
conversion label on valve face.
Figure 13.i Label reverse rating plate
Figure 13.j Conversion label on rating plate label
Figure 13.k Conversion label on valve
Installation