Positioning guide pins
The guide pins of the connector identify the mating receptacle. Position them as shown in the
table below.
Table 4-4 Connectors CN-C1, CN-C2, CN-C3, CN-C4 and guide pins
Connector
Guide Pin
Guide Pin A (Large)
Guide Pin B (Small)
Clamping the cable
Fabrication of cable 10S1261 (connected to terminal board TB-D1
in raise/lower control box)
CN-C1
CN-C2
CN-C3
2
1
1
1
Cable clamp
Figure 4-20 Clamping the cable
Anticorrosive
sheath
Vinyl tape
Fold back shield onto
anticorrosive sheath.
Figure 4-21 Fabrication of cable 10S1261
4-12
CN-C4 Guide Pin Setting Tool
1
3
1
1
Type 10-910-0179-0
Anticorrosive sheath
Shield
35
90
M3 (RED) x 12