Furuno CSH-83 Installation Manual page 23

Color scanning sonar
Hide thumbs Also See for CSH-83:
Table of Contents

Advertisement

Positioning guide pins
The guide pins of the connector identify the mating receptacle. Position them as shown in the
table below.
Table 4-1 Connectors CN-A1, CN-A5, J201 and guide pins
Connector
Guide Pin
Guide Pin A (Large)
Guide Pin B (Small)
Clamping the cable
Fix the cable in the clamp where shield is folded back onto the armor.
Assembling connector NCS-253P (CN-A15)
#2
#3
#1
Solder lead wire to armor and
connect it to #1 pin of connector.
CN-A1
CN-A5
1
5
1
1
Cable clamp
Figure 4-6 Clamping the cable
Armor
Vinyl sheath
Taping
Use cable DPYCY-1.25
(Japan standard cable)
or equivalent cable.
Figure 4-7 Assembling connector NCS-253P
J201
Guide Pin Setting Tool
1
1
Type 10-910-0179-0
Shield + armor
Anticorrosive sheath
Cable DPYCY-1.25
4-5
Armor
Vinyl
sheath
Conductor
2
S = 1.25 mm
= 1.35 mm