5. Position the signal cable so that no more than 4 cm of the sheath is exposed as shown
in the figure below. Tighten fixing bolts.
6. Unfasten four screws shown in the figure below.
7. Pass the signal cable through the cable protector.
Tubing
Within 4 cm
Plate
Flat
washer
CABLE GLAND
How to fix signal cable in cable gland
Antenna unit chassis, cover opened
Antenna unit chassis, cover opened
1-24
Shield
Sheath
Bolt
Gasket
Four screws
Cable
protector