Flush mounting
Note: Use supplied pan head screws when the thickness of the bulkhead is from 11 to 14
mm. For bulkhead which exceeds 14 mm in thickness, the length of the pan head
screws should be bulkhead thickness (A) plus 7.8±1.2 mm. Also the length of B
should be max. 8 mm.
1. Prepare a cutout in the mounting location whose dimensions are as shown below.
2. Attach the flush mount sponge to the display unit.
3. Fix the display unit by using six washer head screws M4x20. Refer to the outline
drawing at the back of this manual.
Note: When installing the display unit in a panel, attach the vinyl tube (ø6, local supply) to
the drain hole to allow moisture to escape. Then, fasten the tube to the drain hole with
a cable tie.
B
A
Fixing screw, side view
6-R2.25
Flush mounting of display unit