ELECTRIC HEAT CAPACITIES

15 kW
Volts
No.
kW
Btuh
Input
of
Input
Output
Steps
208
11.3
38,600
220
12.6
43,000
230
13.8
47,100
240
15.0
51,200
440
12.6
43,000
460
13.8
47,100
480
15.0
51,200
550
12.6
43,000
575
13.8
47,100
600
15.0
51,200
ELECTRICAL/ELECTRIC HEAT DATA
Voltage − 60hz − 3 phase
Compressors
Rated Load Amps each (total)
(3)
Locked Rotor Amps each (total)
Outdoor Fan
Full Load Amps each (total)
Motors (4)
Locked Rotor Amps each (total)
Power
Exhaust
Full Load Amps each (total)
Fans (2)
Locked Rotor Amps each (total)
Service Outlet 115V GFI
Indoor Blower
Motor
1
Minimum
Circuit
Ampacity
without power exhaust
2
Maximum
Overcurrent
Protection
without power exhaust
4
Unit Fuse
Block
without power exhaust LAFB
Disconnect
4
Electric Heat Control Kit
NOTE − Extremes of operating range are plus and minus 10% of line voltage.
1 HACR type breaker or fuse.
2
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
3
Circuit breaker must be field provided.
4
Only used with electric heat.
30 kW
No.
kW
Btuh
of
Input
Output
Steps
1
22.5
76,800
1
1
25.2
86,000
1
1
27.5
93,900
1
1
30.0
102,400
1
1
25.2
86,000
1
1
27.5
93,900
1
1
30.0
102,400
1
1
25.2
86,000
1
1
27.5
93,900
1
1
30.0
102,400
1
Horsepower
Horsepower
3
Rated Load Amps
10.6
Locked Rotor Amps
66
with power
0 kW
76
exhaust
15 kW
76
30 kW
110
45 kW
155
60 kW
164
71
with power
0 kW
90
exhaust
15 kW
90
30 kW
110
45 kW
175
60 kW
175
80
with power exhaust
LAFB90A6
80A6
0−30 kW
45 kW
T1DISC150−1 T1DISC250−1
60 kW
45 kW
No.
kW
Btuh
kW
of
Input
Output
Input
Steps
33.8
115,300
2
45.0
37.8
129,000
2
50.4
41.3
141,000
2
55.1
45.0
153,600
2
60.0
37.8
129,000
2
50.4
41.3
141,000
2
55.1
45.0
153,600
2
60.0
37.8
129,000
2
50.4
41.3
141,000
2
55.1
45.0
153,600
2
60.0
208/230V
15.6 (46.8)
124 (372)
2.4 (9.6)
4.7 (18.8)
1/3 (249)
4.8 (9.6)
9.4 (18.8)
15 Amps
5
7.5
3
16.7
24.2
4.8
105
152
26.8
82
90
37
82
90
37
118
127
55
163
172
77
172
181
82
77
85
35
90
110
40
90
110
40
125
150
60
175
175
80
3
175
200
90
90
110
40
LAFB
LAFB
110A8−2
40A8
LAFB
LAFB
LAFB40A8
90A6
110A8−2
T1DISC150−1
T1DISC250−1
T1EHKT01C−1Y
Page 10
60 kW
No.
Btuh
kW
of
Output
Input
Steps
153,600
2
67.6
172,000
2
75.6
188,000
2
82.7
204,800
2
90.0
172,000
2
75.6
188,000
2
82.7
204,800
2
90.0
172,000
2
75.6
188,000
2
82.7
204,800
2
90.0
460V
7.5 (22.5)
59.6 (178.8)
1.3 (5.2)
2.4 (9.6)
1/3 (249)
2.6 (5.2)
4.8 (9.6)
15 Amps
5
7.5
3
7.6
11
3.9
45.6
66
23.4
40
44
30
40
44
30
58
63
44
81
85
62
85
90
66
38
41
28
45
50
35
45
50
35
60
70
45
90
90
70
90
90
70
40
50
30
LAFB
LAFB
LAFB35A8
45A8
50A8
LAFB
LAFB
50A8
30A10
T1DISC080−1
T1DISC080−1
T1DISC080−1
T1DISC080−1
T1DISC150−1
T1DISC080−1
T1EHKT01C−1G
T1EHKT01C−1J
90 kW
No.
Btuh
of
Output
Steps
230,700
2
258,000
2
282,200
2
307,100
2
258,000
2
282,200
2
307,100
2
258,000
2
282,200
2
307,100
2
TCA180S
575V
6 (18)
49.4 (148.2)
1.0 (4.0)
1.9 (7.6)
1/3 (249)
2.0 (4.0)
3.8 (7.2)
15 Amps
5
7.5
6.1
9
36.6
54
32
35
32
35
47
50
65
68
68
72
30
33
35
40
35
40
50
50
70
70
70
80
35
40
LAFB
40A8
LAFB
LAFB
35A8
40A8

Hide quick links:

Advertisement

Table of Contents